Hayward heater if code - Clean the hayward heater regularly to prevent any debris buildup, which can trigger the if code. Remove leaves, sticks, and other objects from the heater. Check the air filter and clean or replace it as needed. A dirty filter restricts airflow and can cause the heater to overheat, resulting in the if code.

 
For hayward pool heater if code repair, check the pressure switch and ensure proper pressure is being reached. Hayward pool heaters display an "if" code when the pressure switch is not closed. This is caused by insufficient water flow, closed valves, air in the system, or a clogged filter. It is important to identify and fix the issue .... Jory geigle

In this video you'll see how a natural gas pool heater is wired and how the wiring is covered from 240 volts (double pole) to 120 volts (single pole). Also, ...The 5th and 6th digits of the serial number of a Hayward heat pump pool heater are the year of manufacture, and the next two are the month. So the example shown below was produced in August, 2017. This serial number system has been in effect since May, 2010. For models manufactured from 2005 to mid-2010, a typical serial number looked like this ...Raypak 014786-156A Propane Gas Pool Heater 150K BTU for 0-1999ft Elevation. Part Number: 014786. Model Number: P-R156A-EP-C. Click For Best Price. Raypak 266,000 BTU Digital Electronic Ignition Natural Gas Pool Heater. Built to withstand various weather conditions, perfect solution for environments requiring efficiency, …Universal HC Series - Dual Fuel 400k BTU. Hayward. SKU: HDF400. The industry’s smallest footprint heater allows replacement of almost any heater in an existing pad with the efficient reliability of the new Universal HC Series dual-fuel technology heater from Hayward®. Add to Compare. Add to Export. Overview.Hayward H400 trouble code 5F. Our Hayword H400 pool heater won't come on this morning. Display flashes 5F. Filter is clean. Tried shutting down a few minutes and restarting but no change. Reply With Quote.Hayward Pool Product Registration. Register your Hayward equipment now to receive a 90 day extended warranty, expert advice, rebate offers & more!*. June 30, 2023 NOTICE: Any applicable warranty coverage for a product shall not commence prior to the delivery date of that product notwithstanding anything stated elsewhere to the contrary.When it comes to hayward heaters, there are some common bd codes that you might encounter. Bd1 indicates ignition failure, which can often be resolved by cleaning the ignition assembly. Bd2 suggests water temperature sensor failure, which can occur due to a faulty sensor or connection issue. If you see bd3, it indicates high limit switch open ...The Hayward heater LO code indicates a fault in the temperature limit switch, vent pressure switch, or water pressure switch. To fix it, ensure the pump is on, is wired and connected well, the water flow is above the required minimum pressure, the filters are clean.The heater must be installed such that the location of the exhaust gas vent assembly outlet relative to adjacent public walkways, adjacent buildings, openable windows, and building openings complies with the National Fuel Gas Code (ANSI Z223 ; Hayward HDF400 | HDF400 User Manual - Page 13 heater may be installed on either non-combustible heater.Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 34 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 195 lb: Product Width:The heater must be installed such that the location of the exhaust gas vent assembly outlet relative to adjacent public walkways, adjacent buildings, openable windows, and building openings complies with the National Fuel Gas Code (ANSI Z223 ; Hayward HDF400 | HDF400 User Manual - Page 13 heater may be installed on either non-combustible heater.I have a Hayward Pro Heat pump HP13023646 it is 11 months old. Started pool up yesterday, and it fired right up. a few minutes later the code "HP" appeared. the unit shut down for a few seconds and started back up. it runs... you hear it kick in for a few seconds to a minute and then this shut down start up repeats. Set both the pool and spa desired temperature on the heat pump before turning on the remote. Once the remote is calling for pool or spa you will not be able to change the function on the heat pump without turning the remote off. Use Terminals 1 and 2 for 2 wire remote connection. Use Terminals 3,4,& 5. Set both the pool and spa desired temperature on the heat pump before turning on the remote. Once the remote is calling for pool or spa you will not be able to change the function on the heat pump without turning the remote off. Use Terminals 1 and 2 for 2 wire remote connection. Use Terminals 3,4,& 5. May 25, 2022 · You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the “bO” message should appear ... The major reasons for Hayward pool heater code IF/ignition failure include lower gas supply, clogged filter, and malfunctioning of the gas and plumber valve. Also, a faulty transformer, defective flame sensor, bad igniter, and incorrect thermostat temperature setting are the root.First, Power cycle the Omni Controller by selecting the power button at the bottom left of the screen, followed by pressing the shutdown option. Once the controller display is shutdown, turn power off using the breaker, wait 60 seconds and power back up. Wait 3 minutes and then check to see if the connection has been re-established.Its on the front side of the header next to the inlet. You will have to remove the 2 panels that are arounf the inlet manifold. should be like 9 or 10 short hex head screws. once those panels are off you will see 2 wires and a probe screwed into the side of the header, when youre facing the front of the heater. make sure the pump/flow is off to ...Hayward ID Tag that will replace our current serial number system. To the left is an explanation of how to read this number. This ID tag will also list the model number. * Early 1-05 Heat Pumps, Heaters*, Filters, Pumps p, , , p Starting May 1, 2010 and Forward (21) 12-1004-000002006 The 5th -6th number will be the year & theInstall a Hayward replacement for any competitor's pump, heater, filter or other select items. SNAP Snap clear photos of the before & after installation products, the Hayward replacement serial number, and the installation invoice.Pentair Intellichlor IC-60. May 21, 2022. #2. No power switch on the heater. You need to cycle the heater CB to power it down. CE code on the display indicate a display failure. Water gets in around the display and causes the keypad to be non-responsive. The fix is an expensive replacement of the display boards.The Hayward Heater HS code indicates that either your water temperature has exceeded a maximum of 104°F or the water temperature is changing at an unusual rate (faster than 6°F in 60 seconds or less while the heater) is on and firing.Hayward HeatPro Heat Pump 140K BTU | Square Platform | W3HP21404T. 5.0 (2 REVIEWS) As low as $230.66/mo*. Learn About HeatPro Heat Pumps Hayward Pool Heaters.Pool Covers. In addition to heating your pool or spa, you can enhance the warming effect by adding a cover to maintain a comfortable water temperature. Using a swimming pool cover when the pool is not in use can reduce your heating costs by as much as 50-70%. Read Pool Covers Save Water and Energy to learn about additional benefits.Set both the pool and spa desired temperature on the heat pump before turning on the remote. Once the remote is calling for pool or spa you will not be able to change the function on the heat pump without turning the remote off. Use Terminals 1 and 2 for 2 wire remote connection. Use Terminals 3,4,& 5.Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000. Hours Mon-Fri: 8am - 7pm Saturday: 9am - 5pm Sunday: By AppointmentDealing with the Hayward Heater HS IO code can be challenging, but with the right knowledge, preventive measures, and a willingness to explore advanced options, you can maintain a reliable and safe heating system for your pool or spa. Remember that safety should always be a top priority when working with gas appliances, and don’t …Dealing with the Hayward Heater HS IO code can be challenging, but with the right knowledge, preventive measures, and a willingness to explore advanced options, you can maintain a reliable and safe heating system for your pool or spa. Remember that safety should always be a top priority when working with gas appliances, and don't hesitate to ...SPECIFICATIONS AND DIMENSIONS H500FD H400FD H250FD H200FD H150FD BTU/hr 500,000 399,900 250,000 199,900 150,000 Thermal efficiency 83% 84% 84% 83% 82.7%When it comes to appliances like water heaters, knowing their age is crucial for maintenance and replacement purposes. AO Smith, a renowned brand in the water heating industry, has...2. Friendswood/Texas. Nov 18, 2015. #1. I recently had a problem with our Hayward H250IDL2 heater. It showed an "IF" code, which stands for Ignition Failure. I do my own maintenance when I am able to, so I pulled the covers off of the unit and started trouble shooting. I did not manage to resolve the problem, so I called my local pool service ...Key Takeaways. The P5 code on Hayward pool heaters indicates a problem with the pressure switch. Common causes of the P5 code include clogged filters, improper water flow, and electrical issues. Troubleshooting steps for the P5 code involve checking water pressure, inspecting the heat exchanger, and verifying the gas supply.My pool heater would not fire and was showing the LO (low flow) code. This shows where the adjustment knob is on the pressure switch and insight into how to ...View and Download Hayward ABG1001 installation, operation & service procedures online. Above Ground Pool Heater. ABG1001 swimming pool heater pdf manual download. Also for: H100id1. ... (as codes for proper gas line material selection (copper, iron or plastic etc.) LOW PRESSURE NATURAL GAS PIPE SIZING: (Based upon gas pressure of 0.5 psig or ...The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.Common Causes of the H5 Code. When your pool heater displays the H5 code, it typically occurs due to a few common reasons. Troubleshooting h5 code in other pool equipment can help identify the issue. Common misconceptions about h5 code in Hayward pool heaters include thinking it is solely related to a faulty igniter or gas valve.For support during down periods, please contact: Urgent life safety inspections: Dennis Zafiratos at [email protected] or (510) 583-4150. Minor encroachment permit inspection: Ali Tavana at [email protected] or (510) 583-4796. Fire permit questions: (510) 583-4900.You are seeing a code of 888 on your pool heater. To better assist you a photo of the data plate with a Model and a serial number. Will allow me to pull your units specific information. I specialize in Pool & Spa Heat Pumps. I am a Licensed HVAC Contractor. ... Hi , I have a Hayward model H250ED2 pool heater, ...First, reset your heater thermostat. Now, set the temperature point below 104 degrees. Then, set the function "Ok". Always keep the temperature under 104 degrees to allow the heater to heat the water at this temperature. Note: Learn how to fix CE code on Hayward pool heater. 4.Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 22 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 140 lb: Product Width:Enter a postal code to find the nearest Hayward authorized pool professional. ... Heaters (not including Heat Pumps) Heat Pumps. Lighting. Pumps. Variable Speed Pumps ...If the heater is connected to the line side of the circuit it will be powered at all times. In this situation, when the pump shuts down the heater will display a fault code of “LO”. If there is a call for heat and the pump then restarts there will be a 2-minute delay for the heater to fire. After the pump has been running for atWith the hayward pool heater p5 code, you can enjoy efficient and reliable heating for your pool. This innovative heater is designed to provide optimal comfort and convenience, allowing you to enjoy your pool all year round. The p5 code feature offers enhanced diagnostics and troubleshooting capabilities, ensuring that any issues can be …Stumbling upon a 'LO' code on your Hayward heater can be quite the head-scratcher. Don't worry, you're about to unravel the mystery behind this cryptic message. This code typically indicates a water temperature sensor error, but it can also be a sign of other underlying issues with your pool heater. In this article, you'll learn the steps to diagnose and fix the problem, ensuring your pool remainsJan 10, 2024 · Conclusion. In conclusion, troubleshooting the Hayward pool heater code 1F can be done by following a few simple steps. First, check the water flow to ensure there aren’t any blockages or restrictions. Next, inspect the pressure switch for any signs of damage or malfunction. If necessary, clean the heat exchanger to remove any debris or buildup. Here are some of the best outdoor heaters for restaurants to keep your customers warm and cozy when they want to dine outdoors to enjoy a meal. If you buy something through our lin...What Is My Hidden Talent. Flat Creek Lodge Hayward. 10290 Highway 27 South, Hayward, WI 54843.Enter Dates. From $135. Check In. 15 00. Check Out. 15 00.. Browse and compare Hayward motels when you search with Expedia. Read reviews, search by map, and book the best motels in Hayward that suit your needs with …Pumps, Filters, Cleaners, Heaters, Heat Pumps, some Incandescent Lighting and Accessories. Hayward's serial numbers for all products, with the exception of some cleaners, controls, heat pumps and electronic chlorinators, are 17 digits long and begin with the numbers '21'. Often these numbers appear on product labels with spaces or parentheses.Fixing the Hayward Heater AO Code: Now that we’ve identified the common causes, let’s explore the fixes to resolve the AO code issue: Inspect and Clean the Air Intake: Start by turning off the heater and inspecting the air intake. Remove any debris or obstructions that may be blocking the airflow. Ensure the intake is clean and clear.View online or download Hayward H200FDP Troubleshooting Manual. ... Brands; Hayward Manuals; Heater; H200FDP; Hayward H200FDP Manuals. Manuals and User Guides for Hayward H200FDP. We have 1 Hayward H200FDP manual available for free PDF download: Troubleshooting Manual ... BD" Code. 34. EE" or "CE" Code. 36. IO" or "SB" Code. 38. SF" or "HS ...Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools.Hayward H-Series Pool Heater Pressure Switch - FDXLWPS1930. $55.99. Qty: ADD TO CART. IN STOCK. FREE SHIPPING. Details Q&A: Ask a Question Q&A: See Answers (3) Customer Reviews (1) Parts (3) Part # 6223-180. By Hayward Pool Products.Hayward H250FDP pool heater showed SF code. Replaced the thermistor and restarted the power. Display still shows SF code and sevice light on. Cycled the mode button and the blower comes on, but no ign … read moreWhen your Hayward pool heater flashes the ‘bo code’, it’s signaling that there’s an issue with the bypass operation. Here’s a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the ‘bo code’ persists.Hayward H250FDP pool heater showed SF code. Replaced the thermistor and restarted the power. Display still shows SF code and sevice light on. Cycled the mode button and the blower comes on, but no ign … read moreFeb 4, 2020 ... SUPPORT ▻ Buy me a coffee: https://www.buymeacoffee.com/fixitwithjake Pool/Spa Heater Repair- Error Code 05 Flume Sensor 1: ...You may not post new threads; You may not post replies; You may not post attachments; You may not edit your postsPentair Intellichlor IC-60. May 21, 2022. #2. No power switch on the heater. You need to cycle the heater CB to power it down. CE code on the display indicate a display failure. Water gets in around the display and causes the keypad to be non-responsive. The fix is an expensive replacement of the display boards.Hayward HDF400 Pdf User Manuals. View online or download Hayward HDF400 Troubleshooting Manual ... Brands; Hayward Manuals; Gas Heater; HDF400; Hayward HDF400 Manuals. Manuals and User Guides for Hayward HDF400. We have 2 Hayward HDF400 manuals available for free PDF download ... BD" Code. 38. EE" or "CE" Code. 39. IO" or "SB" Code. 40. SF" or ...Hayward H250 Quick Manual (4 pages) Universal H-Series POOL AND SPA HEATERS. Brand: Hayward | Category: Swimming Pool Heater | Size: 0.8 MB. Hayward H250 Pdf User Manuals. View online or download Hayward H250 Installation, Operation & Service Procedures, Installation, Operation And Service Manual, Quick Manual.Ruud hot water heaters can only be purchased through local independent contractors that have been authorized as a Ruud dealer as of 2015. Customers can search for local Ruud author...Interior Designers & Decorators; Architects & Building Designers; Design-Build Firms; Kitchen & Bathroom Designers; General Contractors; Kitchen & Bathroom Remodelers5, 05. Temperature sensor error, or water is dangerously hot. 6, 06. High limit manual reset on heater is tripped. 7, 07. Stuck heater relay. 9, 09. Water pressure fault; pump may be air locked, or water level low. 131.With variable speed pumps, ensure you have the RPM of the filter pump set at 2200 RPM. Check and clean the heaters' heat exchanger. Remove and inspect the High limit sensors, and there are two located in the header of the heater. If there are any signs of corrosion or calcium buildup, replace them.The SF code on your Hayward heater's display stands for "Stack Flue Sensor Failure.". This code indicates that there's a problem with the sensor responsible for monitoring the flue gases in your heater. Flue gases are the byproducts of combustion, and monitoring them is crucial for safety reasons. Common Causes of SF Code.The last number is the unique Manufacturing ID for every Hayward pool heater. So, if you look at your code, it tells you that your Hayward pool salt cell was made in Nashville, TN, in December 2018. March 2010 to July 2015. ... Where is the model number on the Hayward pool heater?Ensure the proper installation of the main circuit board within the heater. Check the short ground and high voltage issue and take steps to prevent it. 5. Circuit Board's Faulty Fuse. Another factor responsible for displaying the Hayward pool heater ce code is the faulty or blown fuse in the heater's circuit board.Locate a dealer near you for all your needs: building or servicing your pool, buying a product, or warranty support.It. The Hayward H-Series H250FDN is extremely reliable and energy efficient. It marries high performance with environmentally responsible low NOx emissions and can provide energy savings of up to 18% compared to other similar pool heaters. Purchased in Sept. 2016, had to replace the heat exchanger once, but we wer.Mar 24, 2023 · Turn off your heater, wait a few minutes, then power it back on. If the AO Code persists, move on to the next step. Check the wiring: Inspect the wiring between the blower vacuum switch and the control board. Look for loose connections, damaged wires, or other signs of wear and tear. If you spot any issues, call a professional for assistance. View online or download Hayward H400FDP Owner's Manual, Troubleshooting Manual ... Brands; Hayward Manuals; Heater; H400FDP; Hayward H400FDP Manuals. Manuals and User Guides for Hayward H400FDP. We have 4 Hayward H400FDP manuals available for free PDF download: Troubleshooting ... Diagnostic Codes and Part Numbers. 19. Troubleshooting Guide. 20 ...Jan 19, 2013 ... Diagnostic Codes For Hayward Heat Pump ; Pool heat pump tips and tricks. ssjpacman · 21K views ; Massive Salvaging Effort at Baltimore Bridge ...Critter ruins the control circuits of a pool heater.In this case, we needed to swap out the display board and the Control board. Are you experiencing a LO code on your Hayward H-Series pool heater? If so, give this video a watch for a few basic tips on how to work through the issue you... With variable speed pumps, ensure you have the RPM of the filter pump set at 2200 RPM. Check and clean the heaters' heat exchanger. Remove and inspect the High limit sensors, and there are two located in the header of the heater. If there are any signs of corrosion or calcium buildup, replace them.The code FLO means "Low or No Water Flow Detected". It is a self-protection mechanism that prevents the heater from operating if there isn't enough water moving through the heat exchanger. If your filter is dirty then indeed you will need to run the pump at a higher speed in order to achieve the minimum GPM for the heater to operate.Hayward 250 pool heater throwing AO code. Replaced control board, blower motor, pressure switch, igniter. Still not turning on. ...The cost of running a pool heater is cheap for solar heaters, around $100-$200/mo for heaters, and in the $200-$400/mo range for gas heaters. Your actual heating costs will vary from month to month, depending on the outside temperature and weather.

Pentair Intellichlor IC-60. May 21, 2022. #2. No power switch on the heater. You need to cycle the heater CB to power it down. CE code on the display indicate a display failure. Water gets in around the display and causes the keypad to be non-responsive. The fix is an expensive replacement of the display boards.. Ihsa 5a football

hayward heater if code

This integrated control board is designed to use with Hayward Universal H-Series Low NOx induced draft heater models H250IDL2, H350IDL2, H400IDL2 and also compatible with Hayward Universal H-Series Low NOx induced draft heater. New part incorporated on all IDL Heaters built after 9/20/04. Weighs 18-1/2-pound.My Hayward h400 pool/spa heater will not turn on any longer. It is getting power but the combustion blower which turns on first is not turning on. There is no gas smell and no igniter spark happening. ... Hi I have a 2 year old Hayward h series heater showing a "bd" code what is wrong? ...Below is the troubleshooting guide for Hayward pool heater error codes. Error codes show up on the digital screen of the H-Series H150, H200, H250, H300, …I have a Hayward h250 pool heater that is knocking and banging after start up i checked and replaced the flow diverter because it was cracked but its still doing it.would the thermostat cause this bec …Hayward pool heaters are equipped with a self-diagnostic system that detects faults and shuts the unit down. If your pool heater is displaying a code, follow these steps to reset the unit: 1. Turn the power off to the pool heater at the breaker box. 2. Wait five minutes and then turn the power back on. 3.Propane heaters can make cold winter nights a lot more bearable. Here's a list of some of the best indoor and outdoor propane heaters to keep you warm this winter season. If you bu...The date of production/manufacture or age of HAYWARD® HVAC equipment can be determined from the serial number. Example serial number styles/formats found: → Style 1: 2113 16 04 101589001 → Style 2: 21120 4 02 000002006Hayward H250FDP pool heater showed SF code. Replaced the thermistor and restarted the power. Display still shows SF code and sevice light on. Cycled the mode button and the blower comes on, but no ign … read moreThis integrated control board is designed to use with Hayward Universal H-Series Low NOx induced draft heater models H250IDL2, H350IDL2, H400IDL2 and also compatible with Hayward Universal H-Series Low NOx induced draft heater. New part incorporated on all IDL Heaters built after 9/20/04.The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.The Hayward heater LO code indicates a fault in the temperature limit switch, vent pressure switch, or water pressure switch. To fix it, ensure the pump is on, is wired and connected well, the water flow is above the required minimum pressure, the filters are clean.Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Phase Heaters: 1.0000: Platform: Square: Pool Type: In Ground: Product Dimensions: 37 " x 30.5 " x 33.6 "Product Height: 37 in: Product Length: 33.6 in: Product Weight: 245 lb:Step 1. Turn off the power supply to the pool heater. Step 2. Wait for at least five minutes to allow the heater to cool down. Step 3. Turn the power back on and press the reset button. This button is typically located near the heater's control panel or on the heater's interior.LO CODE FIXES. Step 1: Inspecting the Water Pressure Switch Wiring. Step 2: Testing Water Pressure Switch Continuity. Step 3: Pressure Switch Adjustment (If Required) Step 4: Temperature Limit Switch Wiring Inspection. Step 5: Continuity Test for Temperature Limit Switches.Jan 19, 2010 · On 1/27/2010 at 7:57 AM, txpoolguy said: CE code indicates "Communication Error". Problem is communication between integrated control board and display board. Display board (DB) is the one mounted on the backside of the keypad. Integrated control board (ICB) is the one back in the heater behind the display board. Hayward H250 Quick Manual (4 pages) Universal H-Series POOL AND SPA HEATERS. Brand: Hayward | Category: Swimming Pool Heater | Size: 0.8 MB. Hayward H250 Pdf User Manuals. View online or download Hayward H250 Installation, Operation & Service Procedures, Installation, Operation And Service Manual, Quick Manual.When your Hayward pool heater flashes the ‘bo code’, it’s signaling that there’s an issue with the bypass operation. Here’s a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the ‘bo code’ persists.Diagnostic Codes and Part Numbers 19-20 1. Heater not powering up 21-26 2. Open FC1&/FC2 Fuse 27-28 3. Open FC3&/F1 Fuse 29-31 4. Open FC4 Fuse 32-33 5. “D” ode 34-35 ... Hayward Part # FDXLFSK19F30 (Qty. 10) G . The control continually compares the set temp to the actual water temp. WhenFirst, reset your heater thermostat. Now, set the temperature point below 104 degrees. Then, set the function “Ok”. Always keep the temperature under 104 degrees to allow the heater to heat the water at this temperature. Note: Learn how to fix CE code on Hayward pool heater. 4..

Popular Topics